The standard 1 Channel 12V 30A Opto Isolated Relay Module, using of High-level voltage signals to trigger, only needs 3mA current signal to drive the 30A load relay. Use of high-quality power relay, high-withstand voltage transistor, red & green signal lights assures accurate and stable performance. Can be used in various types of power control occasions.

1. Using of high-quality relay, normally open relay contacts maximum load: AC 0--250V/30A, DC 0--  30V/30A;
2. Using of high-withstand voltage transistor, strong driving ability, stable performance, trigger current of 3mA;
3. Working voltage:12V

4. The relay using of high-level voltage signals to trigger, high-level voltage signals can be DC power supply positive, also can be microcontroller I/O port set high;
5. The power indicator (red LED), relay status indicator (Green LED);

The relay module outputs(3-wire interface with terminal blocks, very convenient)
1.NO: the relay normally open contacts;
2.COM: the Relay common contact;
3.NC: the relay normally closed contacts.

Question & Answer

Total 10 questions

Q: Q1:Does the module need 2 separate dc power supply,one for the board and another for the relay,or it can be run by 1 single dc supply? Q2: Can I run a 2hp water pump (9 to 12 A)for 30 to 60 minutes using this module? Questioned by seepolash, 26-Apr-2015

1) It's better to use two seperate power supplies but one will work too. 2)yes. Answered by A.R, 27-Apr-2015 10:31 AM

For water pumps the starting current is usually 5-6 times of the fully running current which occurs for maximum 1 second. Are you sure that, your relay can withstand that? Have you tested it? Answered by shariful.sumon, 31-Jan-2016 16:20 PM

No. In that case if it crosses 30A even for a moment, it will not withstand the current. The user gotta make sure that the current never crosses the relay's maximum current rating. Answered by A.R, 31-Jan-2016 17:45 PM

by the way, what is the power rating of the relay? Answered by shariful.sumon, 31-Jan-2016 20:35 PM

We have already provided all the info that we know about this relay. These info are available at the relays body. Power ratings are usually not mentioned in case of relays. Only nominal current is mentioned. Answered by A.R, 01-Feb-2016 10:02 AM

Q: Question 1: Can we use 5V as Signal Or it's need 12V for Signal? Question 2: What is the minimum Voltage for Signaling? Questioned by akteruzzaman, 02-May-2015

12V Answered by A.R, 04-May-2015 10:07 AM

Q: how can I trigger this by Arduino? Questioned by shamimz, 03-Jun-2015

Q: Only the Relay which is used in this module is available in techshop? Questioned by musfikur, 29-Aug-2015

No Answered by A.R, 01-Sep-2015 11:45 AM

Q: can i use 5v for signaling Questioned by shamimz, 01-Sep-2015

NO Answered by A.R, 01-Sep-2015 11:30 AM

Q: Can i use it a air condition (AC) swicthing . Questioned by shurid, 13-Aug-2016

Dear customer, this "1 Channel 12v 30A Opto Isolated Relay Module" will be work within the given voltage and current range: >> 1HP 120VAC >> 1/2 HP 240VAC >> 30A 240VAC If your maximum load is up to this range, then you can use this module. Answered by FAHIM_REAZA, 14-Aug-2016 09:54 AM

where i will connect ac 220 v load???? Answered by zahidhstu, 20-Nov-2016 18:15 PM

Between NO and COM. Answered by A.R, 21-Nov-2016 09:55 AM

Q: I need only relay not module. Can you provide me? Questioned by mtr.eee.sust, 20-Nov-2016

https://www.techshopbd.com/product-categories/relay/804/sla-12vdc-sl-c-techshop-bangladesh Answered by A.R, 21-Nov-2016 10:16 AM

Q: As it is made by techshopbd can you provide me only the pcb usedin th module? Thanks in advance Questioned by zahidhstu, 21-Jan-2017

Sorry. Not possible. Answered by A.R, 22-Jan-2017 09:42 AM

Q: Can this relay be used to drive a DC 24/12 V High Current load? What voltage should we give to the signal pin? Is it Arduino Logic HIGH 5V or transistor shifted 12 V? If it is transistor shifted 12V then why the 12V pins are given? Please clarify. Questioned by Anindya11, 22-May-2018

Please see the specification tab. normally open relay contacts maximum load: AC 0--250V/30A, DC 0-- 30V/30A. 5V must be given to signal pin. Answered by A.R, 23-May-2018 09:26 AM

Q: Can I use this for supplying the 12V DC power to your Automatic Water Pump Controller board power which is same as mentioned in the manual? Questioned by Md_Rafid_Hasan, 23-Sep-2020

Reviews & Ratings

0 Ratings / 0 Reviews

[0]

[0]

[0]

[0]

[0]

Recently Viewed

icon

Help: 09678110110

09.00am - 08.00pm (7 days a week)

icon

Pay cash on delivery

Pay cash at your doorstep

icon

Service

All over Bangladesh

icon

Warranty and Replacement

Up to 1 Year